Simple Pump header: Logo and slogan - 'The Modern Water Well Pump'.

CSS Pop Up Menus Css3Menu.com


Pump Lift: Installation and Use continued...

Continuing Un-install

After removing the pump head, check to make sure stationary O-ring at the top of the riser tube remains there (right, white arrow).

Check o-ring on riser tube.

Lift the pump lift assembly over the riser tube --

Lift pump lift assembly over the riser tube...

-- and gently lower it down onto the well cap.

Lower pump lift onto well cap.

Pay attention to the access ports on the Pump Installation Lift. Rotate the entire mechanism until an access port is positioned to allow an Allen wrench access to the pinch bolt (right -- note the white arrow).

Line up access port to be able to reach pinch bolt of split flange.

Attach the four tensioners. There are two on each side -- only two are visible in the photo.

Note that there are four Allen head bolts (two (2) on each side) that push the bearing down to increase the tension in the belts (white arrow).

You will not know whether they need to be tightened until you start cranking -- next page.

Attach tensioners - two on each side.


next page