Introduction

Thank you for purchasing a Simple Pump gear motor assembly. This Motorized Pump with Linear Bearing Link Drive (LBLD) is designed for use with the Simple Pump model 100 and 125 hand pumps. When assembled and installed on the Model 125, the gear motor is capable of delivering 2.0 gallons of water per minute (GPM) from as deep as 175 feet. Installed on the Model 100, it delivers 1.3 GPM from as deep4 as 225 feet water level.

It is available in two models, one of which accepts 12VDC, the other 24 VDC power, from a source like solar panel or a marine or automotive battery.

The linear bearing link drive translates the rotary action of the Simple Pump 12 or 24 volt DC gear motor to move the pump rod up and down on a precision ground and polished stainless shaft guided by two linear TEFLON bearing carriers.

Specifications

WHEN POWERED WITH 12 VOLTS DC

Motor Rating (12 VDC): .140 HP continuous
Gear Ratio: 30:1
Output Torque (12VDC): 154 in/lbs. continuous
Output Torque Maximum (12 VDC): 175 in/lbs. @ 56RPM @ 16.3 amps
Nominal Output RPM (12 VDC): 57%
Efficiency: 59.5
Full Load Motor Current (12 VDC): 14.6 amps
Allowable Voltage Range (12 VDC): 11.5 to 15 VDC
Typical temperature of casing, operating in 72 degrees F ambient. 110 degrees F

WHEN POWERED WITH 24 VOLTS DC

Motor Rating (24VDC): .151 HP continuous
Gear Ratio: 30:1 @ 91.0% efficiency
Output Torque (24VDC): 195 in/lbs. continuous
Output Torque Maximum (24 VDC): 400 in/lbs. @ 45.9RPM @ 16.63 amps
Nominal Output RPM (24 VDC): 60.1
Efficiency: 64.24%
Full Load Motor Current (24 VDC): 7.32 amps
Allowable Voltage Range (24 VDC): 24 to 30 VDC
Typical temperature of casing, operating in 72 degrees F ambient. 110 degrees F