Hand Water Pumps: Install your water well hand pump.
Introduction to installation prodcedure.
Install Your Simple Pump Hand Pump
Installation Procedure for Model 100L & 125L Hand Pump
|
Page 1 (this page)
|
Section 1 - Introduction |
|
|
Section 2 - Do It Yourself, or Call a Professional? |
|
|
Section 3 - Inspecting Your Existing System |
|
|
Section 4 - Replacing the Existing Well Cover |
|
|
Section 5 - Pump Cylinder & Drop Pipe Installation |
|
|
Section 5 - Continued |
|
|
Section 6 - Pump Head Installation |
|
|
Section 7 - Pumping Water & Finishing Touches |
|
|
Exploded and Cutaway View |
Section 1: Introduction
Thank you for purchasing a Simple Pump. We are extremely proud of the high quality products that we manufacture. We have installed our pumps in a variety of well types and sizes and our instructions are a result of installation experience. Please carefully read through these instructions. Your time will be well spent. At any time, if you think you are overwhelmed, get the help of a professional pump installer.
We will be referring to parts by their part number and name. Use the attached part's list to identify parts as you read through these instructions.
Assembly Parts List
100CA or 125CA Pump Cylinder
PHA Pump Head
SIM020A Top Pump Rod
SIM042 Lever Bracket
SIM021 Lever Link Arm
24LA or 36LA Lever Arm with grip
SIM032 Clevis
90156A383 Clevis Pin (3)
C2, 4, 5, 6, 7, or 8 Well Cover
SIM054A Split Flange
SIM073 Safety Tool
109DPBE Standard Drop Pipe
D2-108 Sucker Rod w/ fused M&F ends
100RG Sucker Rod Guide
109DPTBE-48 Top Drop Pipe
Tools and Materials Needed
Each section also specifies which of these tools are needed for that section.
Allen wrench set (English, not metric)
Safety tool -- included with each pump. This is the fork-shaped tool, SIM073, used while assembling the piping and feeding down the well. It holds the partially-assembled column, preventing it from dropping into the well.
2 channel locks: to grip 1¾” outer diameter PVC pipe
2 vise grips
Roll of Teflon tape
Bleach/water: 1 part bleach to 24 parts water.
Wire cutters, strippers (if installing alongside an existing submersible pump)
next page